X Items in my bag 0
0 £0.00
Menu
MenuX
Latest Offers - Register Now Free Delivery on All Orders Over £99 Order Online - Click & Collect

Fluke 117 Electricians Digital Multimeter with Non contact voltage

Code:
Manufacturer Code:
Manufacturer Code: 2583647
Price £202.80 inc. VAT
Description

Designed by electricians. Engineered by Fluke.

Compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster. 

 

·        VoltAlert™ technology for non-contact voltage detection

·        AutoVolt automatic ac/dc voltage selection

·        Low input impedance: helps prevent false readings due to ghost voltage

·        Large white LED backlight to work in poorly lit areas

·        True-rms for accurate measurements on non-linear loads

·        Measures 10 A (20 A overload for 30-seconds)

·        Resistance, continuity, frequency and capacitance

·        Min/Max/Average with elapsed time to record signal fluctuations

·        Compact ergonomic design for one-handed operation

·        Compatible with optional magnetic hanger (ToolPak™) for hands free operation

·        CAT III 600 V safety rated

Specifications

Maximum voltage between any terminal and earth ground

 600 V

Surge protection

 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2

Fuse for A input

 11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display

Digital:

 6,000 counts, updates 4 per second

Bar graph

 33 segments, updates 32 per second

Operating Temperature

 -10 °C to + 50 °C

Storage Temperature

 -40 °C to + 60 °C

Battery type

 9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery Life

 400 hours typical, without backlight

 


TOP
close x
Thank you for subscribing to the
ToucanTools Newsletter

Accuracy Specifications

DC millivolts

Range:

 600.0 mV

Resolution:

 0.1 mV

Accuracy:

 ± ([% of reading] + [counts]): 0.5% + 2

DC volts

Range/Resolution:

 6.000 V / 0.001 V

Range/Resolution:

 60.00 V / 0.01 V

Range/Resolution:

 600.00 V / 0.1 V

Accuracy:

 ± ([% of reading] + [counts]): 0.5% + 2

Auto volts

Range:

 600.0 V

Resolution:

 0.1 V

Accuracy:

 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts1 true-rms

Range:

 600.0 mV

Resolution:

 0.1 mV

Accuracy:

 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

AC volts1 true-rms

Range/Resolution:

 6.000 V / 0.001 V

Range/Resolution:

 60.00 V / 0.01 V

Range/Resolution:

 600.0 V / 0.1 V

Accuracy:

 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

Continuity

Range:

 600 Ω

Resolution:

 1 Ω

Accuracy:

 Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.

Ohms

Range/Resolution:

 600.0 Ω / 0.1 Ω

Range/Resolution:

 6.000 kΩ / 0.001 kΩ

Range/Resolution:

 60.00 kΩ / 0.01 kΩ

Range/Resolution:

 600.0 kΩ / 0.1 kΩ

Range/Resolution:

 6.000 MΩ / 0.001 MΩ

Accuracy:

 0.9 % + 1

Range/Resolution:

 40.00 MΩ / 0.01 MΩ

Accuracy:

 5 % + 2

Diode Test

Range/Resolution:

 2.000 V / 0.001 V

Accuracy:

 0.9% + 2

Capacitance

Range/Resolution:

 1000 nF / 1 nF

Range/Resolution:

 10.00 μF / 0.01 μF